1.
Interv Neuroradiol ; 24(6): 693-701, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29973083

RESUMO

BACKGROUND AND PURPOSE: A frequently reported drawback of ethylene vinyl alcohol copolymer-based liquid embolic agents is the production of artifacts in diagnostic imaging. New embolic agents, such as Precipitating hydrophobic injectable liquid (PHIL; MicroVention, Tustin, CA, USA), are supposed to induce significantly fewer artifacts. The purpose of this study is to assess the degree of artifacts induced by the liquid embolic agents Onyx (Medtronic Neurovascular, Irvine, CA, USA) and PHIL in conventional computed tomography (CT), cone-beam CT and magnetic resonance imaging (MRI) in an experimental in vivo model. MATERIALS AND METHODS: In 10 pigs the rete mirabile was embolized with Onyx ( n = 5) or PHIL ( n = 5). After embolization, conventional CT, cone-beam CT and MRI were performed. The degree of artifacts was graded qualitatively (five-point scale; for CT and MRI) and quantitatively (HUs of well-defined regions of interest (ROIs); for CT only). RESULTS: Artifacts were significantly more severe for Onyx both in the qualitative (e.g. conventional CT: 2 versus 5 (medians); p = 0.008) and in the quantitative image analysis (e.g. cone-beam CT: standard deviation of a ROI near to the embolic agent cast, 94 HU versus 38 HU (medians); p = 0.008). Neither Onyx nor PHIL produced any apparent artifacts in MRI. CONCLUSION: PHIL produces fewer artifacts than Onyx in conventional CT and cone-beam CT in an experimental in vivo model.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico/métodos , Dimetil Sulfóxido , Imageamento por Ressonância Magnética/métodos , Polivinil , Tomografia Computadorizada por Raios X/métodos , Animais , Circulação Cerebrovascular , Embolização Terapêutica , Interações Hidrofóbicas e Hidrofílicas , Processamento de Imagem Assistida por Computador , Injeções , Modelos Animais , Suínos
2.
J Neurointerv Surg ; 10(11): 1092-1096, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29555871

RESUMO

BACKGROUND: The embolization technique can have significant impact on the success of endovascular embolization. OBJECTIVE: To evaluate the feasibility, embolization characteristics, and embolization extent with a newly developed extra-small micro-balloon catheter in an in vivo and in an in vitro embolization model in comparison with standard microcatheter embolizations. MATERIALS AND METHODS: Twenty-eight embolization procedures were performed in the porcine rete mirabile (RM) and in an in vitro embolization model, using either an extra-small (distal outer diameter 1.6 F) dual-lumen micro-balloon catheter or a standard microcatheter. Precipitating hydrophobic injectable liquid (PHIL) was used as embolic agent. Procedure times, number of injections, required volume of embolic agent, and embolization extent (percentage of embolized RM in postinterventional X-ray scans or number of filled sections of the in vitro model) were assessed. Histopathological analyses were performed. RESULTS: Total procedure time was significantly shorter (in vivo: 123 s vs 615 s (medians), P=0.001; in vitro: 180 s vs 496 s (medians), P=0.001), number of reflux events was significantly lower (in vivo: 0 vs 9 (medians), P=0.001; in vitro: 0 vs 3 (medians), P=0.001), and embolization extent was significantly higher (in vivo: 96.9% vs 65.6% (medians), P=0.011; in vitro: 26 vs 18 filled sections (medians); P=0.041) for the micro-balloon catheter groups. There was antegrade movement of the PHIL cast after balloon deflation in one in vitro embolization procedure and spontaneous balloon deflation with subsequent reflux in one in vivo embolization procedure. CONCLUSION: Extra-small dual-lumen micro-balloon catheters can improve endovascular embolization in comparison with standard microcatheter embolization.


Assuntos
Cateterismo/instrumentação , Catéteres , Embolização Terapêutica/instrumentação , Procedimentos Endovasculares/instrumentação , Base do Crânio/irrigação sanguínea , Animais , Cateterismo/métodos , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Base do Crânio/diagnóstico por imagem , Base do Crânio/cirurgia , Suínos , Resultado do Tratamento
3.
J Neurointerv Surg ; 10(3): 268-274, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28689184

RESUMO

BACKGROUND: The choice of the embolic agent and the embolization technique can have a significant impact on the success of endovascular embolization. OBJECTIVE: To evaluate a novel iodinated copolymer-based liquid embolic agent (precipitating hydrophobic injectable liquid (PHIL)) in the porcine rete mirabile (RM), serving as an endovascular embolization model. Onyx, as an established liquid embolic agent, served as comparator. MATERIALS AND METHODS: Sixteen embolization procedures were performed using PHIL (n=8) or Onyx (n=8) as liquid embolic agent. Waiting time between injections was set to 30 or 60 s (n=4 per study group). Survival time after intervention was 2 hours or 7 days. Embolization characteristics (eg, procedure times, number of injections and volume of embolic agent) and embolization extent (percentage of embolized RM in post-interventional x-ray) were assessed. Post-interventional CT and histopathological analyses were performed. RESULTS: Embolization characteristics and embolization extent were not significantly different for PHIL and Onyx, including subgroups (eg, embolization extent 44% vs 69% (medians); p=0.101). For PHIL, extension of the waiting time from 30 to 60 s led to a significantly higher embolization extent (24% vs 72% (medians); p=0.035). Moderate disintegration and mild inflammation of the embolized blood vessels were present for both embolic agents. CONCLUSION: PHIL is feasible for transarterial embolization in an acute and subacute endovascular embolization model. In this preliminary experimental in vivo study, embolization characteristics, embolization extent, and biocompatibility seem to be similar to those of Onyx.


Assuntos
Modelos Animais de Doenças , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/terapia , Polivinil/administração & dosagem , Animais , Dimetil Sulfóxido/administração & dosagem , Avaliação Pré-Clínica de Medicamentos/métodos , Radiografia Intervencionista/métodos , Suínos , Resultado do Tratamento